Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSAGE HIGHLAND CREEK
Address9246 HIGHLAND CREEK PY
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/3/2026
Final Score @ Grade
14
General CommentsPERMIT RESTRICTIONS: 1). Flow meter must remain operable. Flow required at 152 GPM to 196 GPM to meet turnover and flow restriction of the filters. Flow greater than 289 GPM is a suction hazard. 2). Plexiglas must remain in place on all stone columns to eliminate footholds. NOTE: -This pool ID# 501512 permit denied today due to following noted items on the inspection sheet. - All items shall be repaired/replaced, and ensure it is in good working condition. - Please Contact the department office at 980-314-1620 to request and pay for the return visit prior to re-inspection. The return visit fee is $100. - If you have any questions call EHS: 704-617-9777 or email to obtain the operational permit. - The pool shall remain closed until permit is issued. - NIGHT SWIMMING IS NOT PERMITTED. - CPO: Delmar Evans present during permit inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8.- Observed pH measured 7.0.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching.- Observed several gates around pool deck leading out from resident home are not latching and self-closed. Repair needed.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2519(k) Provide operational pressure gauge on filter.- Observed one of two pressure gauge on sand filter is not working needs repair or replace.