NameHAZEL SOUTHPARK APARTMENTS
Address4401 BARCLAY DOWNS DR
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/6/2021
Final Score @ Grade
8
General CommentsOnsite visit to pool for construction final and operating permit inspection. Dan Ricci and Mike Mossie present during the inspection. Construction final passed with restrictions. 1) Back gate nearest to pump room with latching mechanism not operable. Removed during inspection and permanently disabled shut. Repair gate to self-close, self-latch per rule requirement by follow-up visit. 2) Replace test kit reagents. Permit Restrictions 1) Chicken wire on barrier must remain in place over center of meshing barrier due to size of current barrier openings. Approval by Health Department required prior to removal to ensure meets code restrictions. 2) Stoppers at doors must remain in place to ensure doors do not stay propped open. 3) Perimeter lighting must remain with angles to eliminate footholds. 4) Door to restroom must remain open so restrooms remain accessible to public at all times. Note: Salt is approved as primary chlorination. Pool Width – 15 ft. Rope Length – 22.5 ft. Max Depth – 3 ft. 6 in. Pentair Whisperflo WFE-3, ¾ hp. Skimmers plugged in skimmer. Pool built without main drains or equalizer lines.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid and DPD-1 expired. Provide new reagents for follow-up inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door stoppers installed but doors still open wide and stay open. Screw added to stoppers as temporary repair. Stoppers must remain in place so doors do not stay open when opened wide. Back gate not self-latching. Spring damaged on Aqua-latch. Contractor removed latch at time of inspection and made part of barrier. Repair gate to self-close, self-latch. Will be verified on follow-up inspection.