1
|
6
|
Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
Some sediment on pool bottom and main drain at time of inspection, could not clearly see main drains in good repair. .2535(2) Main drains must be clearly visible from the pool deck. Operator cleaned drains and corrected. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records at time of inspection. Pool has been closed.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Operator recorded all required readings and corrected. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One inlet fitting at time of inspection. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Operator replaced and corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Horizontals on fencing less than 45", 41". Pool and fence built 1996.
.2528(b) Horizontals shall not be located less than 45" in height.
Back gate has been bolted closed to be part of fence. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Cracks in deck by 5' end larger than 1/2" near ladder. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Operator filled cracks with dirt to seal and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No clearance around piping in pump room. Chemicals stored in pump room. Water on floor of pump room. Pool built '96. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. 2533(d) Pump room floor shall be kept dry and free of standing water.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap at sink in women's restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink. |