Return to Inspections
NameELLIS, THE - MID-RISE
Address226 E 9TH ST
 
City/State/ZIP
CHARLOTTE NC 28206
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/28/2021
Final Score @ Grade
16
General CommentsVerified pumps and drain covers: Feature: Hayward SP3207EE 3/4 HP, 2 Aquastar A10RCFR Filtration: Hayward SP3210EE 1 HP, 2 Aquastar A10RCFR, skimmer equalizers lines plugged in skimmer and plastered on wall. Pool not heated. Rope 39'. Changed to "A" Open for Business. Issued local permit sticker. No Night Swimming. Must use stick feeder, do not use automatic acid and chlorine feeder until it shuts off with pump and is verified by Health Dept. Contact Marie Daley at 704-507-6806 for verification when in compliance Salt approved as primary chlorination if handrails are marine grade per mfg instructions. Inspection with Richard Garner No signature due to COVID

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers with debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate had gap greater than 1/2" on right side of latch where sliding tempered glass in fence was moved. Door onto pool deck not latching at time of inspection. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator moved solid gate glass piece to close gap and inserted putty behind it to keep in place. Door adjusted to self-close-self latch. Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs and furniture within 6' of pool at time of inspection. Furniture within 5' of railings and attachments on pool. Pavers removed from decking at time of inspection, creating offsets greater than 1/2" .2522(a) Provide 6 ft of clear walking space around the pool at all times. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Operator moved pool furniture to create 6' clearance around and workers secured pavers to eliminate offsets. Corrected.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automatic feeder not shutting off chlorine or acid when pump is turned off. .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. Operator unplugged feeder as corrective action. *NOTE: This must remain UNPLUGGED AND DISCONNECTED for permit, must use stick feeder. Contact Marie Daley at 704-507-6806 if automatic feeder is corrected and going to be used.