6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
PDSC forms indicate EQK750 pump. Installed EQ750 for both filtration and slide. No suction hazard. Provide updated PDSC by 10/8 or permit will be suspended. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some debris on pool floor and some algae around ladders. Treat as needed and keep pool floor clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some skimmers missing weirs and some debris under skimmer baskets. Keep clean so circulation occurs as required. Replace weirs as needed. Corrected during the inspection. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
No diving marker blocked by basketball hoop. Moved during the inspection.
Depth markers at steps on wall with bottom of lettering shaved off. Not 4" lettering. Install depth markers with 4" lettering per rule requirement. Intent to suspend issued. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One return missing fitting near 3 ft. and overflow missing fitting/cover. Replace fittings where required. Intent to suspend issued. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Doors from kitchen area on to pool deck not self-closing, self-latching. Glass inside kitchen area. Doors shall self-close, self-latch. Intent to Suspend issued.
>4" between lower pickets (bent) at ramp gate. Repair to 4" or less. Intent to Suspend issued.
<30" between horizontal step downs on some fencing. Barrier built 2006.
Wall at handicap gate provides foothold. Located 40" from wall to top of gate. Pool built 2006. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Damage to deck near 4 ft. depth marker. Repair deck where damaged. Intent to Suspend issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Drain cap leaking on one filter. Repair drain cap to ensure no leaks. Intent to Suspend issued. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor wet due to leak at filter. Keep floor dry.
Liquid chemicals storage in pump room. Liquid shall be stored in approved chemical storage room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
One soiled toilet seat in the women's restroom. Keep fixtures clean. |