Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameARWEN VISTA
Address11505 MASTERTON RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/8/2023
Final Score @ Grade
24
General CommentsInspection conducted with CPO Joshua Glisson. Test kit expires 7/23. Provide new test kit or new chemicals prior to test kit expiration. Contrasting color bands peeling in places. Maintain contrasting color bands at least 2” wide at leading edge of steps and benches. Permit condition is that the pump must operate at least 193 GPM to achieve 6 hour turnover. Permit issued No Night Swimming Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some ladders loose. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope heavily knotted. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Post-2010 fencing with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter reads 330 GPM. Max flow of pump is 300 GPM, Max flow allowed by filters is 282 GPM. .2518(g) Install flow meter on return line per manufacturer instructions such that flow meter is accurate to within +/- 10% of true flow. - Will follow up on next inspection.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Faucets in restrooms do not stay activated long enough to wash hands. Have to wash one hand at a time. .2526(m) Keep restrooms and fixtures clean and in good repair. Some stalls in men’s and women’s restroom with broken toilet paper dispensers or are out of toilet paper. .2526(l) Provide toilet paper and dispensers in restrooms.