| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records spotty. No recent records for main drain checks. No total alkalinity or cyanuric acid checks for May. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some leaves on pool surface. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
Tile by skimmer broken. .2537 Maintain pool wall and floor in good condition. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Water level below the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Pre-permit item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
All three ladders loose. .2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
New 60 foot throw rope for ring buoy. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Post-2010 fencing with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Water below the skimmers, skimmer turned off, not able to get reading on flow meter. .2518(g) Keep flow meter operational. - Pre-permit item. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Faucets in restrooms do not stay activated long enough to wash hands. Have to wash one hand at a time. .2526(m) Keep restrooms and fixtures clean and in good repair.
Some stalls in men’s and women’s restroom with broken toilet paper dispensers or are out of toilet paper. .2526(l) Provide toilet paper and dispensers in restrooms. |