Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameARWEN VISTA
Address11505 MASTERTON RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/14/2022
Final Score @ Grade
26
General CommentsInspection conducted with inspector Fonlon Etienne and maintenance staff Patrick Foley. Flow meter read ~145 GPM. Pump must operate at least 193 GPM to achieve 6 hour turnover. Corrected. VFD adjusted from 45 Hz to 55 Hz. Flow changed to ~190 GPM, which is within +/- 10% of what Blue-White flow meter can accurately read. Faucets in restrooms do not stay on when activated, can only wet one hand at a time. Recommend repairing or replacing faucets. Immediate suspension issued 22) Contact Will Harrison (704-507-6824) when issues have been corrected to schedule re-inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No CPO Dylan Davis now working in Georgia. Need to have CPO certified staff that checks the pool at least daily. Patrick Foley will be new CPO, scheduled to take class next month. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item. Records not properly kept. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance activities. Provide recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Four of five weirs missing. .2518(k) Install functional weirs. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy with loose beckets. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Post-2010 fencing with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Intent to suspend item. Back gate recently raised up. Now has gaps > 2" under the gate. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Intent to suspend item. Gate to playground broken. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Emergency phone not operable. .2530(f) Emergency phone shall remain operable. - Immediate suspension item. Old spa area where emergency phone is located is blocked off. .2530(f) Emergency phone shall be accessible to all pool users. - Immediate suspension item. Not able to see emergency phone from most of the pool deck. .2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemical storage room fan not functioning. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Pump room fan not functioning. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.