| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Technician took records home with them yesterday. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Records must be kept onsite. - Corrected, operator checked chemicals today and recorded on a new sheet. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Two ladders loose. .2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
55 foot throw rope for ring buoy. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Post-2010 fencing with two gates and some fence sections with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Corrected.
Post-2010 fencing with gaps > 2" under the fence in places. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Corrected. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone number posted is for main office. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Vacuum cap missing. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemical storage room fan not functioning. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Pump room fan not functioning. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Vacuum line not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. - Corrected. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No toilet paper or holder in one of the stalls in the men's restroom. .2526(l) Provide toilet paper and dispensers in restrooms.
Faucets in restrooms do not stay activated long enough to wash hands. Have to wash one hand at a time. .2526(m) Keep restrooms and fixtures clean and in good repair. |