Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVISTAS @ 707
Address707 SEIGLE AVE
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/24/2021
Final Score @ Grade
28
General CommentsInspection conducted with Marcus Johnson. Due to COVID-19 precautions, inspection was not signed by the operator. Pool pump motor recently replaced. Verified that permit E3925145 was obtained and passed Code Enforcement electrical inspection 3-31-2021. Pre-permit inspection did not pass. 3) 8) 16) 22) 24) A $100 reinspection fee will need to be paid prior to scheduling a reinspection by calling our main office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 8.3. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Two weirs missing, four weirs missing Styrofoam backing, no longer float properly. .2518(k) Replace missing or damaged weirs. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gaps as much as 7" under fence along road. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Pre-permit item. Brick wall < 48" high where wall meets office. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Pre-permit item. Some windows that open onto pool deck missing window limiters. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Pre-permit item.
22 6 Premises: emergency telephone provided No No No Kings III phone does not accept incoming calls. .2530(f) Emergency phone shall remain operable and be able to accept incoming calls. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Pre-permit item. One vacuum line missing self-closing cap, other vacuum line with solid cap. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak at pump. .2533(d) Pump room floor shall be kept dry and free of standing water. Chemical storage room mostly full of furniture and other non-chemical items, difficult to access chemicals. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One light burned out in women's restroom. Three lights burned out in men's restroom. .2526(m) Keep restrooms and fixtures clean and in good repair. No toilet paper in women's restroom. .2526(l) Provide toilet paper and dispensers in restrooms. No soap in men's restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink. Faucet not working in women's restroom. .2526(m) Keep restrooms and fixtures clean and in good repair.