2
|
1
|
Certified Food Protection Manager |
No |
Yes
|
No |
2-102.12 (A) PIC shall demonstrate knowledge by being a certified food protection manager. Observed PIC with expired ANSI food protection manager certification. PIC demonstrated knowledge by answering questions pertaining to food handling and food service during and after inspection. Repeat.
For more information on becoming a certified food protection manager please visit: www.mecknc.gov/foodsafety |
|
47
|
1
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
4-501.12 Resurface or replace cutting surfaces that can no longer be effectively cleaned and sanitized. Observed multiple prep top cutting boards with burn marks and heavily cut or gouged surfaces. Repeat. |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed most shelving units with moderate buildup of soil throughout kitchen. Observed inside of reach in refrigeration units in need of cleaning due to food debris buildup. Observed lids of hot holding pans with heavy food soil. Clean frequently to avoid soil accumulation. REPEAT |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed black buildup on floors beneath stand in place equipment (pizza oven, three compartment sink, etc.) |