NameCORTLAND NODA
Address1700 N BREVARD ST
 
City/State/ZIP
CHARLOTTE NC 28206
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/10/2021
Final Score @ Grade
22
General CommentsImmediate suspension issued for pool chemistry. The pool is not permitted to reopen until a visit is completed by the Department and the pool chemicals are corrected. Call Chris Sells at 704 576-8678 to schedule a return visit. No signature per COVID guidelines

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH over 7.8. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate suspension item
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed main drain checks not consistent. Check drain covers and record daily. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed skimmer baskets collecting debris .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed barrier height at 47" from grade to top of brick wall at fountain area. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. *Intent to suspend item Observed windows to the left and right of the pool rules sign closest to the pump room open over 4". .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. *Intent to suspend
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed 2 chairs within 5 feet of pool edge. .2522(a) Provide 6ft of clear walking space around the pool at all times. Corrected during inspection