Premises Information

Return to Inspections
NameTRADEMARK COA
Address333 W TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/2/2026
Final Score @ Grade
38
General CommentsIntent to Suspend issued for the following: .2535 - lower CYA to less than 100 ppm. .2528 - no access to doors on to pool deck from resident apartments - doors shall self-close, self-latch. .2524/.2537 - pool not approved for night swimming - requires approval or signage changed to reflect day swimming hours. Provide new USCG approved ring buoy and replace rusted screw on body hook within 30 days. Pool floor/chipping paint requires repair prior to 2027 operating season. Chelsea Parker, Trident Pool Group, present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No CYA slightly above 100 ppm. Lower to below 100 ppm. Intent to suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor with chipping/cracking paint. Areas with larger areas of chipping paint require repair prior to 2027 operating permit. Ensure pool floor kept in good repair. No sharp edges at time of inspection.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No No Diving marker blocked by basketball hoop on deck. Moved during the inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Step handrail loose at steps closest to building. Tighten handrail.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No General Comment: Grab rope on ring buoy starting to degrade. Replace with USCG approved ring buoy. One screw bolt rusted body hook. Replace bolt to ensure secure. Ring buoy rope 1 ft too short. Lengthened at tie on during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No No access to resident doors that lead directly on to the pool deck. Doors shall self-close, self-latch or self-close with audible alarm. Intent to Suspend issued.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Pool hours indicate 5 am to 11 pm. Pool is NOT approved for night swimming. Provide documentation that property has sufficient lighting for night swimming approval or adjust hours to reflect dawn to dusk. Intent to suspend issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. If repaired/replaced, install flow meter per NSF approval.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet. Appears to be a leak around heater. Could not locate. Keep pump room floor dry. Eliminate leaks.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >113 F. Maintain at 110 F or below.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bibs in restrooms. Original construction. Provide hose bib with backflow prevention within 50 ft. of restrooms.