Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTRADEMARK COA
Address333 W TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/9/2025
Final Score @ Grade
34
General Comments6 - PDSC form shows pressure gauges in use. Pressure gauge reading higher reading and does not reflect accurate flow on the pump. Flow meter is operable. Provide updated PDSC form within 1 week reflecting use of flow meter for reduction. Granular on pool deck. Operator stated pool was shocked previous day. Advised that pool shall not be shocked while open to the public. Operator swept up granular during inspection. No granular was noted in the pool. Jack Mayo present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No cyanuric acid or total alkalinity records. Maintain weekly records. Operator stated that the pool had been closed throughout the winter and no records were maintained.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Old ring buoy on pool deck. New buoy provided. Rope too long. Corrected to 36 ft. during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Center resident door on to pool deck with audible alarm. Alarm not operable. New alarm delivered and installed while onsite.
22 6 Premises: emergency telephone provided No No No Phone not dialing 911 upon arrival. Corrected during the inspection. Emergency phone not clearly visible from all areas of pool deck. Blocked by landscaping. Provide additional signage at far side of the pool where phone not visible within 30 days. Photograph is ok for documentation. Note: Hornets nest with hornet in emergency phone. Removed during the inspection.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. If replaced, install per mfg. specifications.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak at flow meter. Pump appears to have a small leak. Could not find location of leak. Repair leaks where needed. Leaks did not warrant return visit.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leaks on flow meter and pump (possibly). Keep floor dry.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >113 F. Maintain at 110 F or below. Could not verify mirrors as shatterproof in restrooms. Restroom mirrors shall be shatterproof.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib in restrooms. Original construction. Hose bib shall be provided within 50 ft. of restroom.