Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No cyanuric acid or total alkalinity records. Maintain weekly records. Operator stated that the pool had been closed throughout the winter and no records were maintained. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Old ring buoy on pool deck. New buoy provided. Rope too long. Corrected to 36 ft. during the inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Center resident door on to pool deck with audible alarm. Alarm not operable. New alarm delivered and installed while onsite. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone not dialing 911 upon arrival. Corrected during the inspection.
Emergency phone not clearly visible from all areas of pool deck. Blocked by landscaping. Provide additional signage at far side of the pool where phone not visible within 30 days. Photograph is ok for documentation.
Note: Hornets nest with hornet in emergency phone. Removed during the inspection. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator. If replaced, install per mfg. specifications. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Small leak at flow meter. Pump appears to have a small leak. Could not find location of leak. Repair leaks where needed. Leaks did not warrant return visit. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor wet due to leaks on flow meter and pump (possibly). Keep floor dry. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms >113 F. Maintain at 110 F or below. Could not verify mirrors as shatterproof in restrooms. Restroom mirrors shall be shatterproof. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in restrooms. Original construction. Hose bib shall be provided within 50 ft. of restroom. |