| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
One day missing logs in June. Week in July without CYA or TA readings. Maintain daily record keeping for chlorine, pH and main drain checks. Weekly record keeping for total alkalinity and cyanuric acid. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some algae build-up on steps and near ladders. Continue to monitor. Treat as needed and monitor. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Chip in depth marker at 3 1/2 ft. Depth marker chip over part of the 3. Filled in with sharpie. May require replacement in future if continued issue. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One return missing fitting. Replace fitting on right side wall by main drain. Intent to Suspend issued. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting color band with some chips in paint and faded. Requires repair prior to operating permit 2025.
.2521(b) Provide at least 2" contrasting color band to edge of stair treads. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Center door from patio with audible alarm not operational. Repair door to self-close, self-latch or audible alarm with self-close. Intent to Suspend issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck drains at old waterfall not evenly spaced. Opening >1/2". Corrected during the inspection. Ensure no openings/offsets >1/2" on pool deck. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Warning signage not visible from all areas of pool deck. Move so visible from all areas of pool deck. Intent to Suspend issued.
Provide "Adults should not swim alone." and "Children should not use the swimming pool without adult supervision." in 1" lettering visible upon entry to the pool. Old sign in pump room. Intent to Suspend issued. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator. If repaired/replaced, install with flow meter.
Chlorinator not secured to ground. Recommend securing to ground. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter leaking. Repair leak. Intent to Suspend issued.
PSI pressure gauge does not move when pump is turned off; Hg pressure gauge exceeding gauge max. Could not verify permit restriction. At above 30 Hg, flow does not exceed the drain covers. If gauges are used, pressure shall be capable of reading. Intent to Suspend issued. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Floor wet in pump room due to leak at flow meter. Keep floor dry.
Chemicals storage in pump room. Chemical storage room provided. Store chemicals in chemical storage room. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Hot water in restrooms >113 F. Maintain at 110 F or below. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in restrooms. Original construction. Hose bib shall be provided within 50 ft. of restroom. |