5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
One week with CYA/TA not recorded. Record weekly. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some build-up on pool wall tiles. Keep clean. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One fitting missing on wall at pool step. Corrected during the inspection. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting color band starting to fade in some areas and has small amount of chipping paint. Will require repair within the year. Provide 2" contrasting color band to edge of step or at least 2x2 tile within 1" of step edge. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy rope degrading. Replaced during the inspection. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator. If repaired/replaced, install with flow meter. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operable. True flow required due to new 2017 Aquastar drain covers. Pressure gauges verified at 27.5 psi and 0 Hg. Flow reading off of the pump curve with measurements <119 F. Permit restriction met. Pressure gauges must remain in place. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower not operable. Shower line froze over winter. Provide shower.
Shower sign beginning to fade. Will require replacement in future if worsens. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in restrooms. Original construction. Hose bib shall be provided within 50 ft. of restroom. |