Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No log book. Provide log book with daily record keeping for chlorine, pH and VGBA checks. Total alkalinity and CYA testing weekly. Intent to Suspend issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Two skimmers with weirs stuck. Repaired during the inspection. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Emergency phone blocked by trash can. Phone shall be clearly visible from all areas of pool deck. Trash can moved during the inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Could not verify one door as self-closing, self-latching. Door to far left. Video ok to show self-closing, self-latching. Intent to Suspend issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Damage to concrete near drain cover side of pool deck. Repair concrete to ensure piece does not pop out. Concrete loose. Intent to Suspend issued. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator. If repaired/replaced, install with flow meter. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Coupling leaking after pump near chlorinator. Repair leak. Intent to Suspend issued.
Flow meter not replaced. Required to replace, per previous inspection, due to reading of flow meter not meeting design flow of pump. Install per mfg. instructions. Operator will install new Blue White which ranges as low as 40 gpm. Intent to Suspend issued. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in restrooms. Original construction. Hose bib shall be provided within 50 ft. of restroom. |