Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTRADEMARK COA
Address333 W TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/12/2021
Final Score @ Grade
24
General CommentsIntent to Suspend issued for door on to pool deck. If not repaired prior to May 1, a permit for 2021 operating season will not be issued. Shawn Ready present during the inspection. Permit issued for no night swimming. Pool does not appear to have sufficient lighting for night swimming. Verify lighting is sufficient prior to scheduling a night swimming visit. Permit Restriction 1) Salt not approved as primary chlorination. Note - no placard on pump. 2 hp pump. Appears to be Whisperflo WFE-8, 2 hp pump.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One fitting on pool wall nearest to steps without return fitting. Fitting not threaded. All other returns have fittings. Repair to ensure flow throughout pool. Vacuum line cover not flush to wall. Corrected during the inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope too long. Corrected to 36 ft.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door from middle condo not self-closing, self-latching. Repair to self-close, self-latch or self-close with audible alarm. Intent to Suspend issued. Permit will not be issued on May 1 if not corrected prior to. Windows could not be verified as opening 4" or less due to access. Ensure windows open no greater than 4" on to pool deck from condos.
18 4 Premises: lifeguards present or warning signs posted No No No Adults should not swim alone and Children should not use the swimming pool without adult supervision missing some of the lettering so not a full 1" in height. Corrected with black permanent marker during the inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operable. Corrected during the inspection. Design flow of pump is at 100 gpm. Flow meter only begins at 100 gpm. Ensure correct flow meter installed on the return line. Flow meter not installed per mfg. instructions. Install per mfg. instructions if replaced.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >110 F. Maintain at 110 F or below.