Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
Name1100 SOUTH
Address1100 SOUTH BLVD
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 8/7/2025
Final Score @ Grade
46
General CommentsPermit denied for the following items. .2535 - provide log book with section for main drain checks. .2539 - plug equalizer per State requirement in skimmer. .2518 - provide skimmer weirs where missing. .2530 - provide USCG approved ring buoy with 34 ft. rope. .2528 - secure mesh to gate and repair damage to mesh with openings >1/2" within 18" of push bar or where sharp. .2530 - provide additional warning signage at main entry gate and move pool rules signage to wall of building. .2530 - post address at pool phone. Once items corrected, contact Katie to schedule a return visit. Banks Parmley present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No logs maintained. Log book does not have a section for maintaining daily record keeping for main drains. Provide section in log book for main drain inspections. Permit denial item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC form with incorrect number of skimmers. Should have been listed as 4. Corrected on form. Equalizer lines not plugged in skimmers per State requirement. PDSC form indicates plugged per State recommendations. Plug in skimmers. Permit Denial item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Multiple skimmers missing weirs. Replace weirs. Permit denial item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Deep end ladder not secure. Tighten ladder.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Bubbler returns missing fittings. No offsets >1/2"; no sharp edges. Replace fitting coverings.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Grab rope on ring buoy degrading. Rope for ring buoy degrading. Replace with USCG approved ring buoy and 34 ft. rope. Permit denial item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Main gate entry with meshing not secure and damaged in two locations. Ensure no openings >1/2" within 18" of push bar and secure mesh to barrier. Permit denial item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Turf used on deck within 6 ft. of pool edge. Original construction. Pool furniture 5 ft. from pool. Maintain 6 ft. clearance around the pool with impervious surface.
18 4 Premises: lifeguards present or warning signs posted No No No Warning signage and pool rules signage not visible from main entry gate. Move pool rules signage to wall so visible upon entry to the pool and provide additional warning signage at main entry. Warning No Lifeguard on Duty shall be 4" lettering. All signage shall be visible upon entry to the pool. Permit Denial item.
22 6 Premises: emergency telephone provided No No No No address posted at pool phone. Post address. Permit Denial item.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Shower not operable. Per operator, line broke previous day. Keep all fixtures operable.