2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
0.2 ppm free chlorine. .2535(4) Maintain chlorine at least 1.0 ppm. - Pre-permit item. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Algae growing on pool walls. Debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
No, or very low flow in two skimmers. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Pre-permit item.
One skimmer basket cracked. .2518(k) Replace missing or damaged skimmer basket. - Pre-permit item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Offsets > 1/2 inches where skimmer lids meet pavers. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Pool safety signage not visible upon entry to the pool. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light burned out in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
Standing water in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |