| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Algae growing on pool floor and walls. Debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer missing a weir. .2518(k) Replace missing weirs.
All skimmers with no or little flow. Skimmers on in the pump room. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Intent to suspend item.
Most skimmer baskets with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend issued. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Both handrails missing an escutcheon plate. .2521 Install handrails per manufacturer instructions.
Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
One ladder loose, missing top step. .2521 Install ladders per manufacturer instructions. - This was noted on last year’s inspection as well. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope not attached to ring buoy. .2530(a) Provide 50 foot throw rope at least 1/4 inch in diameter for US Coast Guard approved ring buoy. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Diagonal piece of aluminum added to gate. .2528(b) Horizontals shall not be located less than 45" in height or install metal mesh on outside of gate to eliminate foothold. - Intent to suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
No dialing instructions posted for emergency phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Immediate suspension item. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorine knob turned up on automatic feeder, not feeding any chlorine. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not functioning. .2518(g) Keep flow meter operational. - Intent to suspend item.
Spare pump basket not observed. .2518(e) Provide a spare basket for pump. - Intent to suspend item.
One filter pressure gauge not functioning. .2519(k) Provide operational pressure gauge on filter. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light burned out in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
Pump room very dimly lit. .2533(b) Provide sufficient lighting in pump room.
Standing water in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Lots of general storage items stored by or on pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Fill spout directly on pool deck. .2512(c) Over the rim fill spouts shall be at least two pipe diameters above the deck or pool overflow level. |