| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer missing a weir. .2518(k) Replace missing weirs. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Both handrails missing an escutcheon plate. .2521 Install handrails per manufacturer instructions.
Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
New magnetic latch < 45” from the bottom horizontal on the fence. .2528(b) Horizontals shall not be located less than 45" in height. - Intent to suspend item.
Gate not self-latching and not able to verify electronic latch has a battery backup. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. Electronic gates shall have a battery backup installed. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
Lights not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Pump room floor wet. .2533(d) Pump room floor shall be kept dry and free of standing water.
Some lights burned out in pump room. .2533(b) Provide sufficient lighting in pump room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No toilet paper in men’s restroom. Toilet paper not on a dispenser in women’s restroom. .2526(l) Provide toilet paper and dispensers in restrooms.
Faucet loose in men’s restroom, toilet tank lid missing. .2526(m) Keep restrooms and fixtures clean and in good repair. |
|