General CommentsPre-permit inspection conducted with Sav Douglass. Pre-permit items from previous inspection conducted prior to, or during today’s pool inspection. Mirrors removed from restrooms. Prior to installing new mirrors, will need to provide documentation to this department that mirrors are shatterproof or have properly installed safety backing. Like for like change of pool pump. Electrical permit E4280218 passed inspection 9-15-2022. Outer rope on ring buoy starting to fray. Recommend replacing with new US Coast Guard approved ring buoy before next pool season. Some offsets on pool deck, mainly around skimmers. Maintain with < 1/2” offset. Some wall tiles cracked. Maintain in good condition, recommend replacing. Flow meter heavily worn. Recommend replacing with new flow meter capable of reading to within +/- 10% of true flow. *NOTE* FACILITY PLANS TO INSTALL ROLL-UP/ACCORDION DOOR LEADING FROM CLUBHOUSE TO THE POOL DECK. WILL NEED TO GO THROUGH PLAN REVIEW PRIOR TO INSTALLING THE DOOR TO ENSURE ALL REQUIREMENTS ARE MET. Additional pool log sheets and a copy of the pool permit is available at our website, Meckpools.Charmeck.org. Permit issued No night swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records for today. No main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected. Operator filled out records for today.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer missing a weir. .2518(k) Replace missing weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both handrails missing an escutcheon plate. .2521 Install handrails per manufacturer instructions. Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
22 6 Premises: emergency telephone provided No No No Incorrect address for emergency phone posted. No dialing instructions posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Florescent light not functioning properly in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Pump room floor wet. .2533(d) Pump room floor shall be kept dry and free of standing water.