5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records spotty. No recent Total Alkalinity, Cyanuric Acid, or Main Drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
New CPO for the pool, provide updated CPO information to our department. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer missing a weir. .2518(k) Replace missing weirs. - Intent to suspend item.
One skimmer with plugged return line. .2518(k) Surface skimmers shall be installed per manufacturer's instructions. - Intent to suspend item.
Water level below some of the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Both handrails missing an escutcheon plate. .2521 Install handrails per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope 48 feet long. .2530(a) Provide 50 foot throw rope at least 1/4 inch in diameter for US Coast Guard approved ring buoy. - Immediate suspension item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some deck chairs too close to the pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Urinal in men's room does not fully flush. .2526(m) Keep restrooms and fixtures clean and in good repair.
No toilet paper in men's restroom, toilet paper not on a holder in women's restroom. .2526(l) Provide toilet paper on toilet paper dispensers in restrooms. |