NameHIGHLANDS AT ALEXANDER POINTE
Address310 HIGHROAD DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/5/2021
Final Score @ Grade
36
General CommentsInspection conducted with Matt Love. Due to COVID-19 precautions, inspection was not signed by the operator. Operator's test strips reading significantly lower pH than my DPD test kit. Recommend using a DPD test kit for chlorine and pH. Recommend having automatic chemical feeder recalibrated. Some offsets between pavers and skimmer lids. Ensure that it doesn't worsen and become a trip hazard. Wall tiles very dirty, difficult to read some of the depth markers. Clean tiles regularly. Updated pool log sheets are available on our website, Meckpools.Charmeck.org. Pre-permit inspection did not pass 3) 6) 15) 18) 21) 24) There is a $100 reinspection fee that will need to be paid prior to scheduling a re-inspection. This can be done by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 8.2. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Equalizer line cover with cracked riser ring. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. - Permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both handrails missing an escutcheon plate. .2521 Install handrails per manufacturer instructions. Ladder missing non-slip tread. .2521(b) Ladders shall have slip-resistant tread.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy heavily worn. .2530(a) Provide USCG approved ring buoy. - Pre-permit item. Throw rope frayed. .2530(a) Provide 50 foot throw rope at least 1/4 inch in diameter for ring buoy. - Pre-permit item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some deck chairs too close to the pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
18 4 Premises: lifeguards present or warning signs posted No No No Safety signage not in exact wording. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Pre-permit item.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Large gap between underwater light and light niche. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. - Pre-permit item.