NameCELSIUS
Address10051 PERIMETER STATION DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/15/2026
Final Score @ Grade
20
General CommentsInspection conducted with CPO Brian Roithmeier. Emergency phone cuts in and out, difficult to hear 911 operator. Maintain in good condition. Outer rope on ring buoy and throw rope for ring buoy fraying. Recommend replacing with new US Coast Guard approved ring buoy with attached 40 foot throw rope at least 1/4 inches in diameter. WARNING - NO LIFEGUARD ON DUTY sign heavily faded. Recommend replacing with new sign, ensure in at least 4 inch lettering. Prior to 2026 pool permit being issued will need an updated PDSC form for 5% flow meter. Intent to suspend issued 5) 24) Intent to suspend items and PDSC form must be addressed prior to permit expiration on 5-31-2026 or permit will be suspended.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No weekend records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends more than 6" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. One ladder with bottom step upside down. .2521 Install ladders per manufacturer instructions. - This has been noted on previous inspections. One ladder with loose step. .2521 Install ladders per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing by steps. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - This is a recurring issue. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fencing < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pressure gauge on filter not functioning. .2519(k) Provide operational pressure gauge on filter. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.