Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCELSIUS
Address10051 PERIMETER STATION DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/19/2025
Final Score @ Grade
30
General CommentsInspection conducted with CPO Brian Roithmeier. Throw rope and outer rope on ring buoy fraying. Recommend replacing with new US Coast Guard approved ring buoy and 40 foot throw rope at least 1/4 inches in diameter. Chlorine 10ppm, pH 7.0. Recommend having automatic controller recalibrated. Low flow in the skimmers, not collecting the floating debris on the water surface. Low flow on flow meter. 70 GPM, 72 GPM after a backwash. Recommend having equipment checked. Emergency phone cuts in and out. Recommend having Kings III check the equipment. Intent to suspend issued 5) 7) 8)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records for the last week. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Leaves and debris on pool floor and water surface. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item. All skimmers with no or little flow. Skimmers on in the pump room. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends more than 6" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. One ladder with bottom step upside down. .2521 Install ladders per manufacturer instructions. - This has been noted on previous inspections.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing by steps. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - This is a recurring issue.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door from the restrooms opens with a motion sensor. Was originally approved with a push to exit button. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Standing water on chemical storage room floor. Mold growing on walls and fan. Fan not working. Wall heavily damaged. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Pump room floor wet. .2533(d) Pump room floor shall be kept dry and free of standing water.