Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCELSIUS
Address10051 PERIMETER STATION DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/18/2025
Final Score @ Grade
34
General CommentsInspection conducted with Brian Roithmeier. Main drains and equalizer line covers expire 5-6-2025. Prior to cover expiration, replace with new ANSI/APSP/ICC-16 approved covers and provide updated Pool Drain Suction Compliance form to our office for approval. Equalizer line covers may be replaced or abandoned per state guidelines. Not able to test automatic feeder. Ensure automatic feeder shuts off when the pump is off. Most test kit reagents expired or will be expiring soon. Recommend replacing with new test kit. Immediate suspension issued 3) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 71. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.d
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Log book not observed. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. New maintenance staff. Need to provide updated CPO information to our office. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Leaves and debris on pool floor and water surface. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one of four weirs. .2518(k) Provide functional weirs. Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item. One skimmer lid broken. .2518(k) Replace damaged skimmer lid. - Intent to suspend item.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Missing two depth markers at pool steps on pool wall. .2523(a) Provide depth markers on pool walls and pool deck at points of maximum and minimum depths. - Intent to suspend item. Missing two depth markers at pool steps on pool wall. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends more than 6" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. One ladder with loose bottom step. .2521 Install ladders per manufacturer instructions. - This has been noted on previous inspections. One ladder loose. .2521 Install ladders per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing by steps. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - This is a recurring issue.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automatic feeder not working. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.