Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCELSIUS
Address10051 PERIMETER STATION DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/23/2024
Final Score @ Grade
20
General CommentsInspection conducted with CPO Bradley Bell. Main drains and equalizer line covers expire 5-6-2025. Prior to expiration, will need to replace with ANSI/APSP/ICC-16 approved drain covers and provide updated Pool Drain Suction Compliance form to MeckPools@MeckNC.gov for approval. Difficulty hearing Kings III and 911 operator. Recommend checking the emergency phone. Pool permit expires 5/31/2024. Permit will be suspended if intent to suspend items have not been corrected by this date. Intent to suspend issued 5) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records on Sundays. No recent total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one of four weirs. .2518(k) Provide functional weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends 8" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. One ladder with loose bottom steps. .2521 Install ladders per manufacturer instructions. - This was noted on the last inspection as well.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing by steps. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.