Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCELSIUS
Address10051 PERIMETER STATION DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/24/2023
Final Score @ Grade
38
General CommentsInspection conducted with CPO Bradley Bell. Rocks in some of the skimmers. Use only NSF approved skimmers and skimmer weights. Main drain off in the pump room. Low flow in most skimmers, ensure pump, impeller, and filter working properly. Maintain proper pool turnover. Intent to suspend issued 5) 7) 16) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.4.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records not kept onsite. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Black algae growing on pool floor and around drain covers. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one of four weirs. .2518(k) Provide functional weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends 8" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Two ladders with loose bottom steps. .2521 Install ladders per manufacturer instructions. - This was noted on the last inspection as well.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing by steps. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Two gates not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Unable to call back to emergency phone. .2530(f) Emergency phone shall remain operable. - Will follow up with facility to ensure it is corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pressure gauge on filter not functioning. .2519(k) Provide operational pressure gauge on filter. - Intent to suspend item.