NameCELSIUS
Address10051 PERIMETER STATION DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/30/2023
Final Score @ Grade
16
General CommentsInspection conducted with maintenance staff. Left and came back to verify phone was fixed. On second visit Cl > 10ppm, pH 7.3. Issues from previous inspection corrected. NOTE* Not able to add #15 to the inspection form. 15) New ring buoy with 45 foot throw rope. .2530(a) Provide USCG approved ring buoy with attached 40 foot throw rope at least 1/4 inch in diameter. - Corrected. Permit issued No Night Swimming Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 8.1. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.6.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends 8" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Two ladders with loose bottom steps. .2521 Install ladders per manufacturer instructions.
22 6 Premises: emergency telephone provided No No No Unable to call back to emergency phone. .2530(f) Emergency phone shall remain operable. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.