Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCELSIUS
Address10051 PERIMETER STATION DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/24/2023
Final Score @ Grade
22
General CommentsInspection conducted with CPO Bradley Bell and maintenance staff. Updated database with Bradley’s CPO information. Recommend recalibrating chemical controller. Not much suction in far skimmers, low flow according to flow meter. Ensure that filter is backwashed as needed and sand is cleaned/replaced as needed to maintain proper turnover. Pre-permit inspection did not pass. 3) 5) 15) 16) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 7.0. Operator adjusted to 8.4. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Spotty records. Main drains only checked once every few days. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends 8" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed Styrofoam ring buoy. .2530(a) Provide USCG approved ring buoy with attached 40 foot throw rope at least 1/4 inch in diameter. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door from the clubhouse and door from the restrooms with a motion sensor. Was originally approved with a push to exit button. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Pre-permit item. One gate not self-closing. .2528(a) Access gates shall swing away from the pool and be self-latching. - Corrected.