3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH < 6.8. Operator able to adjust to 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Spotty records. No recent total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item.
Test kit expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Pre-permit item.
Facility has a new CPO. We do not have their CPO records on file. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Pre-permit item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder extends 8" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope and grab rope on ring buoy dry rotted. .2530(a) Provide USCG approved ring buoy with attached 40 foot throw rope at least 1/4 inch in diameter. - Pre-permit item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door from the clubhouse restrooms with a motion sensor. Was originally approved with a push to exit button. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Pre-permit item.
One gate not self-closing. .2528(a) Access gates shall swing away from the pool and be self-latching. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. |