Premises Information

Return to Inspections
NameCELSIUS
Address10051 PERIMETER STATION DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/17/2021
Final Score @ Grade
40
General CommentsInspection conducted with Josh Reed. Due to COVID-19 precautions, inspection was not signed by the operator. Pump motor recently replaced. Ensure that electric permit and passing inspection are obtained from Code Enforcement. This will need to be completed prior to pool permit issuance. Modem dialing sounds when talking on emergency phone. Recommend checking phone system to clean up the lines. No place on log sheet for main drain checks or daily maintenance activities. Can get state pool log sheet from our website, Meckpools.Charmeck.org to print and use. Recommend placing a chemical safety placard on the chemical storage room door to alert the fire department of hazardous chemicals in the event of a fire. Ensure that magnetic latches for gates and doors operate on a battery backup or fail closed in the event of a power outage. Inspection did not pass. A $100 reinspection fee will need to be paid prior to scheduling a follow up inspection. This can be done by calling our main office (980) 314-1620 and paying with a credit card. Permit Denied Pump motor electrical inspection 8) 12) 15) 16) 17) 18) 22) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Three weirs missing. .2518(k) Replace missing weirs. - Pre-permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder step installed upside down. .2521 Install ladders per manufacturer instructions. Some ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook installed on a collapsible pole. .2530(a) 12 foot pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. - Pre-permit item. Provide throw rope too short. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope at least 1/4 inch in diameter. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door from the clubhouse with a motion sensor. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Pre-permit item. Windows opening onto the pool deck do not have window limiters installed. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Pre-permit item. Two gates with magnetic latches < 45" high, creating a foothold. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item. Magna-latch for gate < 54". .2528(a) Gate latches shall be 54" in height. - Pre-permit item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck with large gaps where expansion joint material has worn away. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item. Inadequate deck clearance. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Pre-permit item. Deck chipping by pool steps. .2537(2) Decks shall be kept in good repair.
18 4 Premises: lifeguards present or warning signs posted No No No WARNING - NO LIFEGUARD ON DUTY signs not visible from all entrances upon entry to the pool. Recommend relocating from the gate to the main pool area. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. - Pre-permit item. Missing CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION signage. - .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Missing ADULTS SHOULD NOT SWIM ALONE signage - .2530(c) Provide "Adults should not swim alone." in 1" lettering.
22 6 Premises: emergency telephone provided No No No Emergency phone number not posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.