Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCELSIUS
Address10117 STATION WALK WAY
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/10/2026
Final Score @ Grade
18
General CommentsPOOL IS NOT APPROVED FOR NIGHT SWIMMING. SIGNS GIVE THE CLOSING TIME OF THE POOL AS 9PM. THE POOL CANNOT BE OPEN FOR SWIMMING AFTER SUNSET OR BEFORE SUNRISE. CHANGE THE SIGNS TO REFLECT THIS, FOR EXAMPLE THEY COULD READ “POOL OPEN FOR SWIMMING FROM DAWN TO DUSK” OR “POOL OPEN FOR SWIMMING FROM SUNRISE TO SUNSET”. MAIN DRAIN COVERS EXPIRE 5/6/2027 EQUALIZER LINE COVERS EXPIRE 5/15/2030 INTENT TO SUSPEND ISSUED FOR THE BROKEN LADDER, THE MISSING LADDER TREADS, AND “WARNING NO LIFEGUARD ON DUTY” SIGN. DEADLINE IS 10/10/2026. Offsets between deck and coping. Prior to 2027 pool permit being issued will need to eliminate offsets.Spots on pool floor and sunshelf where plaster is gone exposing the pool shell. Prior to 2027 pool permit being issued will need to replaster the pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed some damage to interior of pool. This must be corrected prior to the 2027 pool season. Keep pool interior in good repair.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 1 weir missing out of 5 total skimmers.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. .2521(b) Ladders shall have slip-resistant tread. Observed 1 ladder to have the top rung broken off. Observed several ladders missing some of the non-slip tread. The metal stairs do not have any tread ridges or or other molded tread features. Intent to Suspend Issued. Deadline is 10/10/2026. Failure to correct the item may result in the closure of the pool.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Offsets between deck and coping. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. These must be corrected prior to permitting for the 2027 pool season.
18 4 Premises: lifeguards present or warning signs posted No No No Warning - No lifeguard on duty sign fell down behind bushes. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering for all the letters. On the current sign, the red letters are 4 inches tall, but the white letters measure less than 4 inches. - Intent to suspend item.