Inspection Date 5/15/2026
Final Score @ Grade
44
General CommentsInspection conducted with CPO Brian Roithmeier. Some places on pool floor where plaster has worn thin and is missing. Maintain pool plaster in good condition. If it deteriorates further will need to replaster. Emergency phone number written on tape. Recommend providing new emergency phone signage with correct address, phone number, and dialing instructions. Throw rope unraveling. Recommend taping or burning the end of the rope to keep it from further deteriorating. Intent to suspend issued 5) 13) 16) 17) 18) 24) Intent to suspend items must be corrected prior permit expiration on 5-31-2026. Failure to make corrections will result in a suspension of the pool permit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No weekend checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir stuck. .2518(k) Provide functional weirs.
13 4 Pool maintenance: contrasting band on steps and benches No No No Some contrasting tiles missing on pool steps. .2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the stair tread. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Magnets for gates not on a battery backup. Latch missing on main gate. .2528(a) Access gates shall swing away from the pool and be self-latching and self-closing. - Intent to suspend item. Side emergency egress gate with push to exit button engages before able to unlatch and open the gate. .2528(a) Access gates shall swing away from the pool and be self-latching and self-closing. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Offsets between deck and coping. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item. Gaps between coping and deck throughout. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item. Some coping and decking loose or with sharp chipping. .2537(2) Decks shall be kept in good repair. - Intent to suspend item.
18 4 Premises: lifeguards present or warning signs posted No No No Warning - No lifeguard on duty sign fell down behind bushes. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Phone number no longer legible. This was an issue last year as well. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pressure gauge on filter not functioning. .2519(k) Provide operational pressure gauge on filter. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. - Corrected. One light not working in pump room. .2533(b) Provide sufficient lighting in pump room. - Corrected. Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.