NameCELSIUS
Address10117 STATION WALK WAY
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/13/2022
Final Score @ Grade
16
General CommentsInspection conducted with inspector Fonlon Etienne and maintenance staff Will Boozer. Maintenance not present for entire inspection, not able to check restrooms, or all gates. Will check on return visit. New fan installed on top of existing squirrel cage fan in chemical storage room. Does not appear to meet code requirements. Does not appear to be properly shielded, spliced into extension cord that runs across the ground. Ensure electrical permits and inspections are obtained from Mecklenburg County Code Enforcement for any electrical work done. Observed rocks in skimmer baskets. Recommend using NSF approved weighted skimmer baskets. Observed back-up erosion chlorinator removed, some water bypasses the filter. Recommend removing the bypass and plugging the holes in the piping for better water filtration. Intent to suspend issued 5) 16) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed a few occasions where pH was out of range on consecutive days with no corrective actions noted. 2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity. New maintenance staff. No staff that is CPO certified. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Tread missing from one of the ladders. .2521(b) Ladders shall have slip-resistant tread. Handrail not installed in anchor on pool steps. .2521 Install handrails per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate by pump room not self-closing if opened all the way. Most other gates locked, unable to test. .2528(a) Access gates shall swing away from the pool and be self-latching and self-closing. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule .2534. Bag of dry chemical on the ground. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.