Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCELSIUS
Address10117 STATION WALK WAY
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/7/2021
Final Score @ Grade
28
General CommentsInspection conducted with Squire Cross, Chazz Staten, and Amanda Salter. Due to COVID-19 precautions, inspection was not signed by the operator. Issues with automatic controller feeding chlorine and acid. Have Caribbean recalibrate and repair as needed. Recommend having some chlorine tabs on hand for the backup chlorinator. Recommend re-caulking around coping where caulking has worn away. Pre-permit items from previous inspection have been addressed. Permit issued with the following condition: No Night Swimming Paper permit will be on our website, Meckpools.Charmeck.org in 3-5 business days to print for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Corrected to 3 ppm.
3 6 Water quality: pool water pH No No No pH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.3.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Facility drained and refilled to lower cyanuric acid levels, water still below the skimmers when inspection started. .2518(k) Water level shall be maintained to assure skimmers are operable. - Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook not securely attached to the pole. .2530(a) Provide at least 12 ft. long, non-collapsible pole with body hook securely attached. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum cap lid broken off. .2518(f) Provide self-closing vacuum cap for pools built after May 1, 2010. - Corrected.