Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCELSIUS
Address10117 STATION WALK WAY
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/28/2021
Final Score @ Grade
26
General CommentsInspection conducted with Amanda Salter and maintenance staff. Due to COVID-19 precautions, inspection was not signed by the operator. Some items from previous inspection have been corrected. PH in log book consistently 6.2 or 6.8. Operator added additional Cyanuric Acid based on 50ppm test results. Cyanuric Acid is now so high that the pH is essentially locked at 6.9 until Cyanuric Acid levels are reduced. Recommend using DPD or another more accurate test kit than test strips. Recommend having automatic chemical controller recalibrated. Pre-permit inspection did not pass. 3) 5) 15) 22) A $100 reinspection fee will need to be paid prior to scheduling a reinspection by calling our main office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 6.9. pH locked due to high Cyanuric Acid levels, operator tried but was unable to adjust pH. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid tested at over 100ppm. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. - Pre-permit item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook not securely attached to the pole. .2530(a) Provide at least 12 ft. long, non-collapsible pole with body hook securely attached. - Pre-permit item.
22 6 Premises: emergency telephone provided No No No Unable to call emergency phone, number goes to fax machine. .2530(f) Emergency phone shall remain operable and be able to accept incoming calls. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Bags of sodium bicarb on the ground in the chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Some lights not working in the restrooms. .2526(m) Keep restrooms and fixtures clean and in good repair.