NameELEVEN240
Address10655 TISBURY RD
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/10/2025
Final Score @ Grade
20
General CommentsInspection conducted with CPO Chauncey Smith. Chauncey is the new CPO for this pool. Updated CPO information. Immediate suspension issued 15) Re-inspection scheduled for tomorrow at 10:00 AM. Can contact Will Harrison (704) 507-6824 to reschedule if needed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Missing one eyeball fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy with 42 foot throw rope. .2530(a) Provide US Coast Guard approved ring buoy with attached 46 foot throw rope at least 1/4 inch in diameter. - Immediate suspension item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates by grills and pump room not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Corner piece of coping by bench loose. .2537(3) There shall be no loose coping. - Intent to suspend item. Tops of some of the skimmers sunken into the deck. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. - Corrected. Some chemicals and other items stored next to pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.