Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameELEVEN240
Address10655 TISBURY RD
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/1/2021
Final Score @ Grade
32
General CommentsInspection conducted with Chris Garcia. Due to COVID-19 precautions, inspection was not signed by the CPO. Recommend providing a chemical safety placard on the chemical storage room door. Ensure that all ladders and handrails are rated for saltwater. Pool using salt for secondary chlorination. Posted pool hours are 9 AM to 9PM. Either change pool hours to reflect that pool closes at dusk or schedule a lighting inspection to ensure pool and required deck space has sufficient lighting. Recommend posting COVID-19 safety signage as required by North Carolina Executive Orders. Inspection did not pass. All items noted as Pre-permit item will need to be corrected before a permit can be issued. A $100 reinspection fee will need to be paid prior to scheduling a reinspection. This can be done by calling our office (980-314-1620) and paying with a credit card. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent records. Last month's records missing TA, CA, and Main Drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Corrected. Operator took chemical readings today.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir floating in the skimmer. .2518(k) Replace missing weirs. Corrected by operator.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fencing along road with one picket not fully secured, gap greater than 4 inches. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Pre-permit item. Sections of fencing along road with very little pine straw. Gaps as much as 4 inches under the fence. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Pre-permit item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some deck chairs and set of table and chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Pre-permit item.
18 4 Premises: lifeguards present or warning signs posted No No No Some safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Pre-permit item. Some safety signage missing. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Pre-permit item.
22 6 Premises: emergency telephone provided No No No Phone number posted is for the main office, not the number for the emergency phone or what 911 has. 911 does not have the correct address for the pool. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Spare pump basket not observed. .2518(e) Provide a spare basket for filtration pump. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan in pump room not functioning. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. - Pre-permit item.