| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No total alkalinity or cyanuric acid checks for July and August. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Equalizer lines on all of the skimmers tabbed closed or plugged .2518(k) Surface skimmers shall be installed per manufacturer's instructions. - Corrected, plugs removed or tabs slid to the side to allow equalizer lines to operate per manufacturer’s instructions.
Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Escutcheon plates missing for most of the handrails. .2521 Install handrails per manufacturer instructions.
Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3” to 6” measured from wall. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door to office not self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some chairs too close to the edge of the pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Spare pump basket not observed. .2518(e) Provide a spare basket for pump. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not functioning in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower not functioning. .2526(h) Shower(s) shall be provided. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No toilet paper in restrooms. Some stalls missing toilet paper dispensers. .2526(l) Provide toilet paper on toilet paper dispensers in restrooms.
No floor drain in men’s restroom. .2526(c) Restroom floors shall be slip resistant and sloped to floor drains to ensure positive drainage. |