Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMARIGOLD THE
Address1801 WILLOW HAVEN LANE
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/24/2022
Final Score @ Grade
14
General CommentsInspection conducted with Henry Ramirez. Verified Intelliflo XF 3 HP pump set at 3110 RPM. Flow meter reads 160 GPM. Observed teal dot on new Aquastar A8Rxxx equalizer line covers. New SDX2 main drain covers also installed. Permit items from previous inspection have been corrected. Cover for floor drain missing in pump room. Recommend installing a floor drain cover. Permit issued. No night swimming. Paper permit will be available on our website, Meckpools.Charmeck.org in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Escutcheon plates missing for some of the handrails. .2521 Install handrails per manufacturer instructions. Ladder missing endcaps. .2521 Install ladders per manufacturer instructions. Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3” to 6” measured from wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to fitness center not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected
18 4 Premises: lifeguards present or warning signs posted No No No Missing safety signage. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light not working in the pump room. .2533(b) Provide sufficient lighting in pump room. Fan in the chemical storage room not functioning. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Light not functioning in the chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Fan not functioning in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower not functioning. .2526(h) Shower(s) shall be provided.