3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Escutcheon plates missing for some of the handrails. .2521 Install handrails per manufacturer instructions. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope for ring buoy 61 feet long. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope at least 1/4 inch in diameter. - Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some depth and no-diving tiles on the pool deck are loose. .2522(g) Decks and walkways shall be slip-resistant. - Pre-permit item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Cannot call to or from emergency phone. .2530(f) Emergency phone shall remain operable. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan in the pump room not functioning. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Light not working in the pump room. .2533(b) Provide sufficient lighting in pump room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some piping faded. .2518(d) Piping and valves shall be labeled with color codes or labels. |