3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. pH measured at 6.8. CDI - adjusted to 7.2 during inspection. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Body hook mounted on collapsible pole <12’. CDI - body hook mounted on solid 12’ pole. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching. Gate by main road did not self-latch. CDI - operator adjusted latch during inspection and gate self-closes/self-latches. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Flow meter not operational. CDI - operator cleaned flow meter during inspection and flow meter began operating normally. |