2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm. Chlorine in pool at 0ppm.
Immediate suspension. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door not latching or alarmed onto pool deck from fitness center. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operational at time of inspection. .2518(g) Keep flow meter operational. Operator corrected to make operable. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No backflow prevention on hose bib in pump room. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap. Pool built 2000. |