NameCOURTNEY RIDGE APTS
Address920 YORKMONT RIDGE LN
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/11/2021
Final Score @ Grade
18
General CommentsIntent to Suspend (ITS) for records, gates self-closing-self-latching, flow meter. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. "W" ITS status Note: Clubhouse has plans for remodel. Ensure in-field plan review application is submitted prior to work to avoid permit action/issues. All windows and doors onto pool deck must meet compliance. Main drains (2 Aquastar 9 MF) expire April 2022, replace and submit updated PDSC for approval prior to expiration to avoid permit action. Inspection with Stephen Gibbons No signature due to COVID Pool not heated. No Night Swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Weekly cyanuric acid missing and some daily recordings not recorded on day of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing at time of inspection. .2518(k) Replace missing weirs. Operator found weir to replace. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Piece of plywood against back fence creating horizontal less than 45"in height. Columns with horizontals against fence less than 45" in height. Pool built 2000. Operator moved plywood and corrected. Horizontals from columns from pre-2010. .2528(b) Horizontals shall not be located less than 45" in height. One gate hinge broken at time of inspection. Not latching. .2537(b) All gates and doors shall be self-closing, self-latching. *Permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational at time of inspection. .2518(g) Keep flow meter operational. *Permit item
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.