16
|
0
|
Food-contact surfaces: cleaned & sanitized |
No |
No
|
No |
4-602.12 (B) The cavities and door seals of microwave ovens shall be cleaned at least every 24 hours by using the manufacturer's recommended cleaning procedure. Observed heavy debris and buildup in cavity of microwave. Clean more frequently. |
|
22
|
1.50
|
Proper cold holding temperatures |
Yes |
Yes
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P Observed container of soup in WIC holding above 41F. CDI PIC voluntarily discarded. Raw beef and chicken were holding above 41 in WIC. Possibly from employees prepping earlier in the day. Observed all other items in WIC and ambient holding below 41F. Items began to cool rapidly. PIC needs to ensure TCS items are being cooled and held in cold holding properly. Reduction to 1/2 points for improvement of cold holding. Repeat
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed gasket torn and hanging on tall RIC. Replace |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed residue on handles of RICs, Observed debris in RIF. More frequent cleaning is required. Observed outside of containers stored clean with sticker residue on outside, returned to dish area. Ensure stickers and residue are completely removed in wash process. |
|
54
|
0
|
Garbage & refuse properly disposed; facilities maintained |
No |
No
|
No |
5-501.113(B) Keep dumpster, outside waste containers covered with tight-fitting lids or doors. Observed doors open on dumpster. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. -Observed broken floor tiles throughout facility. Repair damaged flooring. Fixed WIC flooring by putting removable and cleanable mats down. |