| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
1
|
Handwashing sinks, supplied and accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf
No hand towels at hand sink. CDI by adding hand towels. |
|
14
|
1.50
|
Food-contact surfaces: cleaned and sanitized |
Yes |
No
|
No |
4-602.11 Clean the equipment and utensils used with nonTCS foods as required to avoid contamination.
Observed build-up inside ice machine.
CDI by cleaning ice machine |
|
21
|
1.50
|
Proper date marking and disposition |
Yes |
No
|
No |
3-501.17 Date mark/label all TCS foods that are ready-to-eat once opened or prepared and held more than 24hrs. -Pf
Observed cooked chicken without date mark. CDI by date mark. |
|
26
|
1
|
Toxic substances properly identified, stored, and used |
Yes |
No
|
No |
7-201.11 Store toxic materials to avoid contamination. -P
Observed chemical cleaners stored on the 3 comp sink during use.
CDI by moving to chemical storage area. |
|
34
|
0
|
Thermometers provided and accurate |
No |
No
|
Yes |
4-302.12 Provide an accessible thermometer for use. Provide a thin probe thermometer for accurate measure of thin foods.-Pf
PIC provided an oven thermometer during inspection. Obtain a thin probe thermometer . |
|
43
|
0
|
Single-use and single-service articles; properly stored and used |
No |
No
|
No |
4-903.11(A) Store single-use and single-service articles to prevent contamination and at least 6 inches off the floor.
Observed single service cups stored on the floor. |
|
45
|
0
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
No
|
No |
4-205.10 Ensure equipment other than toasters, mixers, microwaves, water heaters and hoods is ANSI certified or equivalent.
Observed household freezers in use. Replace with commercial freezers. |
|
47
|
0.50
|
Non-food-contact surfaces clean |
No |
No
|
No |
4-601.11(C )/4-602.13 Keep the equipment clean to avoid build up of dust, food residue or debris.
Observed build-up inside upright freezers and cooler. |
|
53
|
0.50
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed water damaged ceiling tiles in the dry storage room.
6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable.
Observed acoustical ceiling tile in kitchen. Replace with washable tile. |
|
54
|
0
|
Meets ventilation and lighting requirements; designated areas used |
No |
No
|
No |
6-303.11 Intensity-Lighting - C
Observed light out in dry storage room. |