3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8.
Operator adjusted to 7.6. Corrected. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing maintenance. Records not accurate at time of inspection. Expired reagents in test kit. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.
Operator provided new test kit and corrected.
**Permit item. Will check on records |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Items within 3’ of equipment. One bucket of chemicals in equipment room.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |